Date of Analysis :January 24, 2020 / July 06, 2020
A. PHYSICAL TEST RESULT
PUMPING STATION | PHYSICAL TEST | METAL ANALYSIS | ||||
TURBIDITY | Color | Arsenic | Cadmium | Lead | REMARKS | |
PNSDW LIMITS | 5 NTU | 10 ACU | 0.01 mg/L | 0.003 mg/L | 0.01 mg/L | |
1. Pump # 1 - Existing | 0.25 | 3 | <0.008> | <0.001 | <0.005 | PASSED |
2. Pump # 3 | 0.9 | 3 | <0.008> | <0.001 | <0.005 | PASSED |
3. ENRICA | 0.2 | 3 | <0.008> | <0.001 | <0.005 | PASSED |
4. Pump # 4 | 0.2 | 3 | <0.008> | <0.001 | <0.005 | PASSED |
5. SAWMILL | 1.2 | 5 | <0.008> | <0.001 | <0.0013 | PASSED |
6. MAGSAYSAY 1 | 0.25 | 3 | <0.008> | <0.001 | <0.005 | PASSED |
7.MAGSAYSAY 2 | 0.3 | 3 | <0.008> | <0.001 | <0.005 | PASSED |
B. CHEMICAL TEST RESULT
PUMPING STATION | Fecal Coliforms | E.Coli | pH |
Chlorine, Residual |
Total Dissolved Solids | Nitrate | REMARKS |
PNSDW LIMITS | <1.1 | Negative | 6.5 - 8.5 | 0.3-1.5 | 500 | 50 | |
1. Pump # 1 - Existing | <1.1 | Negative | 8.2 | 0.7 | 227 | 0.1 | PASSED |
2. Pump # 3 | <1.1 | Negative | 7.9 | 0.6 | 150 | 0.1 | PASSED |
3. ENRICA | <1.1 | Negative | 8.2 | 0.6 | 216 | 0.03 | PASSED |
4. Pump # 4 | <1.1 | Negative | 8.2 | 0.6 | 228 | 0.6 | PASSED |
5. SAWMILL | <1.1 | Negative | 8.4 | 0.36 | 133 | 11.28 | PASSED |
6. MAGSAYSAY 1 | <1.1 | Negative | 8.2 | 0.7 | 204 | 0.01 | PASSED |
7. MAGSAYSAY 2 | <1.1 | Negative | 8.3 | 0.7 | 200 | 0.01 | PASSED |